I have a JobinYvon Spectrum ONE CCD 3000 and I am controlling it with LabVIEW 5.1 on windows 98. I can run the image acquisition vi but after it takes one image, it freezes the connection to the ccd controller. So if I try to rerun the vi, or any other vi communicating to the ccd, it doesn't work. Has anyone come up with a solution to this problem or has anyone come across it before?
ARC-Pocket software (Pocket PC2002/2003 software for Uniden BC785D/BC796D). This is the software only and is for controlling the 785/796 scanners located very close to the Pocket PC. Product Code: 01-520841. A manufacturer of scanners, digital cameras, LCD projector, CD-RWs, and DVD players for PC and Mac Computer.
Is it a hardware or software problem.I thought perhaps the vi's were causing a problem with the ccd because it is Liquid Nitrogen cooled and this is not meant to be done unless the ccd is initialized, but there is no way to just initialize the ccd with labview that I can see. Any thoughts? Dear ShellpetalThe initialization of the camera has nothing to do with its cooling.
Bear Ccd 3000 Software Free
The controller (the big box) has a heater circuit controlling the Temperature (Set to 140K).There are manuals and which should help you understanding the init process.Image acquisition (depending on the binning) takes with today's state of the art PCs and the desired (see manual 1) NI GPIB card up to 15 seconds with an integration time of 1000ms.Sending malformed commands (slightly wrong syntax) can crash the controller easily. Therefore: Go to NI MAX, Open a VISA session with the controller and send a the string 'DE' without 'r'.It is what they call ' in the manual. This resets the controller to the so called boot-mode.Actually, all the numbers you will see in the manual that are in those brackets should be converted to hex. Will be DE.Please use 'Query' to send the command to get a immediate response.You can probe the state of the controller sending a 's' (whitespace, again without term(ination) char(acter)). It should reply with 'B' for boot mode.After initialization it will respond with 'F'.
If you get a 'b' this means that your command could not be identified. In order to bring the controller from Boot to Main send the command 'O200000' (now with the term char 00 or x00). After probing with 's' you should get 'F' now as a response.Now, use the CCDInit.VI in the LIBCCDsupllb directory and try to init the CCD or the Demo VIs in LIBCCDdemollb. There, the CCD is being initialized before doing anything.I attached the VIs to control the CCD. I suppose you are not working with that thing after 7 years but maybe somebody else does.Good luck and have a nice day.JW. Dear JW-WSI,I also have an ISA Spectrum One CCD and purchased recently a CCD-3000v controller for it.
Bear Ccd 3000 Software Reviews
The CCD is mounted in a 2.8l side-looked LN2 housing as discribed in manual (1). It has a label with 'model no. F09' but unfortanetly this is all information I have.It is already possible to acquire a spectrum but there is still something odd. As you can see in the attachement the baseline is around 900 and a weak signal results in a dip. Fallout new vegas raider.
If the signal increases the dip decreases until 220 and a peak within the dip is formed.If I take a 2D image most of the time a horzontal stripe pattern is shown.Both effects indicate a wrong readout or interpretation of the CCD.Are there specific CCD parameters the controller needsThank you very much for your help. Dear NIHugo,I am not an expert on what CCD controller (either ccd3000 or ccd3000v) is the one that suits you best. My CCD has the model number H07. The number is on the label near the flanche. My ccd3000v controller has the same H07 printed on its identifier label.If you take a careful look into the VIs, you can see that the VIs load an.ini file in the CCD/ directory, as well as driver tabels. Maybe you load the wrong ones.
I contacted Horiba JobinYvon lateley and they told me that there is no service anymore for that devices if they break, but the guys at Horiba are very friendly and maybe they could help you out with that.What signal do you mean? For me, the spectrum looks mirrored. Could ou be more precise about you setup?Best regards. Dear JW-WSI,The serial of my CCD-3000V controller ends with /R16, so maybe there is a mismatch. Well, in the manual of the controller several different CCDs are described, therefore I hoped they are compatible. Since the VIs do not crash, no erros occur and I get something similar to a spectrum I have the feeling that I am already so close. I will contact Horiba for assistance.The CCD is mounted to a SPEX1404 double-monochromator and I checked a green emission line of a mercury lamp.
The standard AutoCAD hatch files are acad.pat and acadiso.pat (aclt.pat and acltiso.pat for LT).Adding supplementary hatch patterns supplied by Autodesk to use within an AutoCAD Product. All the hatches available from Autodesk are already packaged within the installed software. Download hatch pattern for autocad.
The spectrum should therefore have a baseline of 0 with a more or less narrow peak in the middle. When I open the slits, the peak should increase and broadens.Do you have friendly contact person at Horiba besides info@jobinyvon?;-). Dear NIHugo You cant say it like that. The baseline is most probably not zero, due to finite thermal and electrical noise at 140K. My SpectrumONE CCD has a baseline of about 1021 Counts/1sec integration time. Your spectrum definately looks like a real one, but flipped.
Due to the flatness of your darknoise level i suppose you acquired the spectrum at your low temperature setpoint. You could negate your spectrum manually and add the baseline levelSo you do not see an increase in counts when increasing the power?I guess we are out of topic now. You can write me a PM. Best regards, JW-WSI.
90 Years Of Doingit Right!AT BEARALIGN.COM, ourmission is to become the leading provider of High quality wheelservice Equipment & Training to the Automotive & TruckingIndustry in the Midwestern USA.No matter what your needs are inwheel service, BEAR branded products are available. Alignment,Lifts, Wheel, Balances, Tire Changers and more.GOLDSTANDARD 5 YEAR Warranty is Only Possible Because BEAR Dependability IsLegendaryWho is Cartek and What Happened to Bear? Cartek has been a largeinternational distributor for Bear since the 1980's. In the 90'sthey started producing the software updates for SPX / BEAR and thenthrough an agreement with SPX in 1998 were licensed to produce allnew Bear equipment through CartekEngineering and manufacturing.Since that time Cartek has designed and manufactured the SML and theMBA series of aligners. They also sold and distributed the Roboticaligner as well as high quality tire changers, wheel balancers, andlifts under the Bear / Cartek label. In July of 2009, Cartek droppedthe Bear label and will from this point forward continue business asnormal under the Cartek product label.
BEARALIGN.COM will continueto service discontinued Bear equipment. NOTHING has changed, justthe logo.i-MoteThe revolutionary device that is re-inventing wheel alignment.Portability these days is KEY, especially in the world of WheelAlignment.MBAThe Multi Bay Alignment SystemIt's all about freedom and taking control of your business.It’s All Here - The Complete Tru Align System!The Tru Align system consists of fourprecision plates and eight sets of steel adapters thattemporarily replace the lug nuts while the alignmentprocedure is taking place. The 155-piece kit allowstechnicians to perform accurate alignments on virtuallyany vehicle on the road in North America, using theircurrent alignment machines and tools.HeavyDuty Truck & Bus Wheel Alignment OptionsNow Available!Total Dimension 2000 4000 & 6000 SeriesmoreThe RoboticAligner'Proven TechnologyNO RIM CLAMPS REQUIREDmoreSML 2000 Economy SeriesmoreTireChangers & BalancersmoreModular SystemFor your PCmoreLiftsmoremore. BEAR ROBOTICS Clamp-less Wheel Alignment System, powered byLasatron ®.
Ccd Camera Software
100's Of MillionsAlignments Performed at OEM Assembly Plants Worldwide.No other aligner canmatch the speed & accuracy we offer.PERIODThe most popular wheel alignmentsystem in the world is now available for your shop!Watch the demo to appreciate the significance of this technologyNew for 20095 year warrantyOn All SML AlignersNew Products!HEAVY TRUCK& BUSManuals For BEAR PRODUCTS NOW AVAILABLE in serviceslinkCall us for Service &upgrades to your BEAR & other make Wheel alignment,diagnostic 'Big Box' Engine Analyzers, and 4 gas benchrepair.more.Bear Low Cost of Ownershipis a design consideration. The Rugged construction &Upgradeability of early CCD models is legendary.more.Chicago & MidwesternUSA Region DistributorWI, IA, IL, INPh: 847-530-6717email: info@bearalign.com.